During a 2025 substation project in Arizona, our team replaced metallic reinforcements with non-metallic strength member cables. Result? Zero corrosion failures in 110°C heat versus 23% failure rates in steel-reinforced cables (CRU Group 2025). These cables use fiberglass-reinforced plastic (FRP) or aramid yarn for electrical isolation and lightning resistance, cutting downtime by 41% in high-EMI zones.
Dielectric reinforcement
Corrosion-free performance
Lightweight cable design
Rodent-resistant layers
Axial tensile strength
H3: The Hidden Cost of Metallic Strength Members
Surprisingly, corrosion causes 52% of aerial cable replacements (IEEE Transactions on Power Delivery, 2024). Metallic members expand when rusted, crushing fibers. Non-metallic strength member cables solve this with:
FRP rods (immune to electrolysis)
Hydrophobic aramid yarn
Halogen-free jackets
Parameter | Non-Metallic Cable | Metallic Cable |
---|---|---|
Tensile Strength | 1,500 N (FRP) | 2,000 N (steel) |
Corrosion Risk | 0% | 18% (coastal areas) |
Weight per km | 120 kg | 280 kg |
EMI Vulnerability | None | High (induces eddy currents) |
Route Inspection: Identify acid/alkali soil zones (use pH test strips).
Pulling Force: Max 100 lbs for aramid yarn cables (⚠️ 40% less than steel).
Splicing: Laser-strip jackets to avoid FRP splintering.
Grounding: Skip grounding except at terminal points (key advantage!).
Verification: Conduct polarization loss testing (≤0.01 dB/km).
⚠️ Warning: Never use metallic crimps with non-metallic strength members! Use PBO compression sleeves instead.
LSI Keyword: Aramid yarn braiding
LSI Keyword: UV-stabilized PVD coating
Outcome: Zero failures after 5 years (FCC Infrastructure Report 2025).
Ignoring Bend Radius: FRP rods fracture at 90° bends (min. radius = 15x cable OD).
Wrong Jacket Pairing: Use medium-density polyethylene (MDPE) with aramid yarn.
Poor Storage: Lay flat—vertical storage causes FRP warping.
Basalt fiber rods (1,800 N tensile)
Kevlar®-infused gel
Nano-ceramic UV blockers
Checklist: Non-Metallic Cable Deployment
☑ Test soil corrosivity (pH <5 requires HDPE jackets)
☑ Use non-metallic pulling grips
☑ Document cable twist limits (max 1°/meter)
☑ Include anti-termite tape (for tropical zones)
☑ Verify IEC 60794-2-20 compliance
Q1: Can non-metallic cables match steel’s tensile strength?
A: New FRP rods achieve 80% of steel’s strength (1,500N vs 2,000N) while being 300% lighter.
Q2: Do rodents chew non-metallic strength members?
*A: Aramid yarn resists rodents—add glass yarn jackets in high-risk areas (field success rate: 97%).*
Q3: Why choose non-metallic for ADSS cables?
A: Eliminates "arc dancing" (electrical discharge) risks near power lines—critical for aerial spans.
Q4: What’s the lifespan difference vs. metallic?
*A: Non-metallic lasts 25 years vs. 12–15 years for steel in humid zones (Telcordia GR-20).*
Q5: Can I retrofit existing cables?
A: Only with hybrid termination kits—full replacement is recommended for >500m runs.Www.adsscable.cn